Wet location. Enclosed and gasketed linear ambient LED luminaire. UL listed for wet locations. Weather and chemical resistant, corrosion free, and impervious to vapors, dust, and moisture. Food handling and processing facilities, refrigerated storage, drug and chemical plants. Use in shower areas, parking garages, pedestrian and roadway tunnels, and outdoor public areas. Injection molded high transmission frosted acrylic diffuser.

Ul l501

Building and fire codes require fire and smoke protection features to safeguard building occupants from fire hazards and hazards associated with smoke and hot toxic gases generated during a fire situation. This includes requiring fire-resistance-rated assemblies, such as fire walls, fire barriers, fire partitions, shaft enclosures and horizontal assemblies be provided to limit the spread of fire. This system of passive protection is an integral part of the overall fire safety approach taken by the model codes. This marking and application guide provides important information on limiting the spread of fire, smoke and toxic gases by protecting duct penetrations and air-handling openings in fire and smoke rated assemblies. There are five types of dampers recognized by the model codes for this purpose: fire, smoke, combination fire-smoke, ceiling and corridor dampers. UL certifies all five types of dampers in accordance with the requirements in model building, fire, and mechanical codes. These dampers and the applications for which they are certified are covered in detail in this guide. There are also duct protection methods that are an integral part of fire-resistance rated assemblies, and are described within the designs. See section 3. For information on smoke control systems, see NFPA Product iQ is free to use, but does require a one-time registration. UL has developed this guide for use by code and inspection authorities, architects, contractors, installers and other interested parties. It is intended to aid in understanding the types of dampers which exist, in association with the applicable codes and standards to facilitate safe, code-compliant installations. UL Marking and Application Guides are updated as necessary due to new product development, changes in the codes, or the need for clarification. This guide is intended to assist users to locate, specify or verify the correct type and code compliant UL Listed damper based on the use and installation location.

Where a vertical duct penetrates a horizontal assembly without a shaft enclosure, a horizontal fire damper is required. These dampers and the applications for which they are certified are covered in detail in this guide, ul l501.

.

We use cookies to provide a personalized site experience. By continuing to use and browse this site, you agree to our Privacy Policy. Forgot your password? Sign In. Create an account. Please enter the email address you used to create the account. We'll send you a link that lets you create a new password. It looks like you entered an employee email address, but this is the customer sign-in. Use the link below instead. Your password must be at least 8 characters, including at least 1 number and at least 1 capital letter.

Ul l501

Occasionally code authorities ask to receive copies of UL standards that are referenced in the code they are enforcing. In most cases it is not necessary to obtain the actual UL standard to determine code compliance. That information should assure code authorities that a product was evaluated to the appropriate product standard, as referenced in the code. If there is a need to access the UL Standards this can now be done using our complimentary web based service. To learn more about creating an account and accessing UL Standards for free visit this page. If you would like further information please visit the UL Standards home page for more information. Leave a message or send an email and we will respond promptly. UL Standards.

Btone phone

It is intended to aid in understanding the types of dampers which exist, in association with the applicable codes and standards to facilitate safe, code-compliant installations. Further, the mullions are limited to use in vertical partitions. Heavy Duty Current: 96Amps. The installation requirements of NFPA include topics such as damper location, damper actuator and linkage, access to fusible links and serviceability. Normal Duty Current: 96Amps. The maintenance requirements include topics such as changes in the airflow and noise from the duct, lubrication and required documentation. L , L and M It does this by regulating the installation, operational testing, periodic inspection and maintenance of these dampers. Quick view. This includes requiring fire-resistance-rated assemblies, such as fire walls, fire barriers, fire partitions, shaft enclosures and horizontal assemblies be provided to limit the spread of fire. Voltage: V. Dynamic ceiling dampers are required at locations in which fan pressure and airflow remain in operation during a fire incident. These devices are installed to operate automatically, controlled by a smoke detection system, and, where required, capable of being positioned from a remote command station. Although these ratings relate to individual dynamic ceiling damper models it is important to note that both static and dynamic ceiling dampers do not have an assigned hourly fire-resistance rating. The fusible link must be reinstalled after testing is complete.

Navigate your business in an increasingly complex world with industry-leading research and actionable insights from UL Solutions. Explore our press releases and news updates. Delve into detailed press kits for information on our work.

Highlights Intuitive control panel and PC tool Direct torque control DTC for precise open and closed loop control Built-in safety features for simplified configuration Communication with all major automation networks Removable memory unit for easy drive commissioning and replacement Energy optimizer and energy efficiency information for monitoring and saving energy Designed for easy service. If a fusible link appears to be damaged or painted when inspected, it must be replaced with a listed link that is functionally equivalent and has the same temperature and load rating. Voltage Range: V. Smoke dampers are designed to operate against air velocity and fan pressure. Carolina Motion Controls Videos. Corridor dampers are investigated for use in specific horizontal ceiling constructions as specified in the installation instructions supplied with the product. UL listed for wet locations. The ratings must be compatible with the ratings of the smoke damper. Each category code provides a link to the published product GuideInfo for that product and links to the products certified within that category. This method of construction consists of a combination of protecting the inside of rectangular shaped steel ducts with a minimum 1 in. Heavy Duty HP: 7. The operational test shall demonstrate the damper is installed and functions as intended. Authorities having jurisdiction should field-test various combinations of opened and closed dampers to represent the worst expected condition across the damper.